R134A Air Conditioning DHW DC Inverter Heat Pump 10.9KW

Brand Name : LN

Model Number : DKFXRS-11II/R

Certification : CE ISO CCC

Place of Origin : China

MOQ : Negotiable

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 80000pcs/year

Delivery Time : 1-30 working days

Packaging Details : standard export package, or as per customer request

Type : Air Source Heat Pump,Water-Cooled,Economical big/ large monoblock,High temperature industrial heat pump

Storage / tankless : Storage,Instant / Tankless,Circulation heating

Installation : Freestanding,Wall Mounted/Freestanding

Use : Bathroom,spa,Swimming Pool Heater,Hotel,School,Space Heating

Refrigerant : R410A,R407C,R407C/R32/R22,R410a/ R417a/ R407c/ R22/ R134a,R410a/R407c/R22

Compressor : *MitsubishI* Inverter Twin Rotary Compressor,Copeland,*Copeland* top series,Copeland scroll compressor,Rotary

Contact Now

Description of 10.9 kw heating and air conditioning domestic hot water(DHW) heat pumps:

A heat pump water heater control system based on the Internet of Things is adopted. The data acquisition unit is used to collect preheating information and indoor air temperature information, and the data processing unit is used to receive preheating information and air temperature information and process them to obtain preheating. Processing information and air temperature processing information, using the data analysis unit to receive and analyze the preheating information and air temperature processing information to obtain the analysis data, and send the analysis data to the control and adjustment unit, and use the control and adjustment unit according to the first preheating information And the second preheating information respectively control the operation of the heat pump water heater in the morning and evening until the heat pump water heater’s preheating temperature reaches the preheating standard value for heat preservation treatment; all aspects disclosed in the present invention are used to solve the problems in the existing solutions The problem of automatic preheating according to the user’s work and rest time, and the problem of poor control of the preheating effect of the heat pump water heater

Application of air source heat pumps

Air Source Heat Pump Air Conditioning provide house heating and hot water,wherever need hot water, energy saving and more economical, not feel dry,it is widely use in hospital,sauna,factory,commercial centre,slaughter, swimming pools, spas, etc

Company introduction

Decades production experience, its own labotory, over 380patents, norminated supplier for buildings, leader member for ediiting air source heat pumps standard, about 80000pcs air to water heat pumps production capacity a year!

Quality control:

100% inspection for each product, 3 phrases test before delivery, free spares supply, good prize if found any unqualified items

Production line:

3 production lines to guarantee production capacity and quick delivery, 2 shifts working

Low temperature hot water unit parameters
Spec. DKFXRS-11II/R
Nominal heating capacity at room temperature(kW) 10.9
Nominal heating at room temperature(kW) 2.65
Low-temperature
nominal heating
capacity(kW)
4.75
Low temperature nominal heating(kW) 2.15
Maximum input power(kW) 4.2
Maximum current(A) 8
Power Specifications(Hz) 380V 3N ~ 50
Refrigerant/charge amount R22/5600g
noisedb(A) <62
Water resistancekPa <55
Anti-shock level I
waterproof level IPX4
Caliber of inlet
and outlet
DN32
Unit size (mm) 1030x410x1390
Unit Weight(kg) 142
Spec. DKFXRS-38II/R
Nominal heating capacity at room temperature(kW) 38.8
Nominal heating at room temperature(kW) 8.8
Low-temperature
nominal heating
capacity(kW)
17.7
Low temperature nominal heating(kW) 7.35
Maximum input power(kW) 17
Maximum current(A) 30
Power Specifications(Hz) 380V3N ~ 50
Refrigerant/charge amount R22/6700gx2
noisedb(A) <68
Water resistancekPa <100
Anti-shock level I
waterproof level IPX4
Caliber of inlet
and outlet
DN40
Unit size (mm) 1550x780x1700
Unit Weight(kg) 431

R134A Air Conditioning DHW DC Inverter Heat Pump 10.9KW


Product Tags:

DHW DC Inverter Heat Pump

      

8A DC Inverter Heat Pump

      

R134a DC Inverter Heat Pump

      
Best R134A Air Conditioning DHW DC Inverter Heat Pump 10.9KW wholesale

R134A Air Conditioning DHW DC Inverter Heat Pump 10.9KW Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Maanshan Leonon Energy Saving Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)